System Sensor Duct Detector Wiring Diagram

The detector housing shall be ul listed per ul 268a specifically for use in air handling systems.
System sensor duct detector wiring diagram. It shows the components of the circuit as streamlined shapes as well as the power as well as signal links between the gadgets. Smoke introduced into an air duct system will be distributed throughout the entire building. The flexible housing of the duct smoke detector fits multiple footprints from square to rectangular. Model ductsd duct smoke detectors utilize 4 wire photoelectric technology for the detection of smoke.
Alarm red led power green led common. One unit can accommodate multiple installation footprints to overcome mounting constraints. The innovairflex d2 2 wire photoelectric duct smoke detector features a pivoting housing that fits various applications. System wiring diagram for dh400 2 wire duct smoke detectors wiring diagram for rts451key remote test station to dh400 2 wire duct smoke detectors.
This detection method when combined. Innovairflex duct smoke detectors combine an impressive collection of innovations to greatly simplify hvac system monitoring. Model d4120 and d4s duct smoke detectors utilize 4 wire photoelectric tech nology for the detection of smoke. Smoke introduced into an air duct system will be distributed throughout the entire building.
Smoke detectors designed for use in air duct systems are used to sense the presence of smoke in the duct. 15 19 14 3 20 1 3 alarm signal 2 aux. Hvac duct smoke detection. The air duct smoke detector shall be a system sensor innovairflex d4120 photoelectric duct smoke detector.
Wiring diagram shown is for dh100acdclp 4 wire duct smoke detector system equipped without a control panel. Ductsd duct smoke detector the system sensor ductsd series duct smoke detectors with a cover integrated smoke test port and fl exible confi gurations provides effi cient installation and maintenance. Both square and rectangular footprints mount to round or rectangular duct work. Duct detector method 2 aux power located at test station caution.
A wiring diagram is a simplified traditional pictorial depiction of an electric circuit. This new duct smoke detector senses airflow speeds ranging from 100 to 4 000 feet per minute with proven system sensor precision. Break wire runs to provide system supervision of connections. Smoke detectors designed for use in air duct systems are used to sense the presence of smoke in the duct.
This new detector features low flow tech nology that enables duct smoke detection throughout a broad range of airflow. Features 4 wire photoelectric integrated low flow technology air velocity rating from 100 ft min to 4 000 ft min 0 5 m s to 20 32 m sec. Totaline duct smoke detector duct smoke detector the totaline p270 2000pl is a 4 wire photoelectric air duct smoke detector capable of sensing smoke in air velocities from 100 to 4 000 ft per minute 0 5 to 20 32 m sec. Variety of duct smoke detector wiring diagram.
This detection method when combined with an.